
CnergyPro Infrastructure
Five scopes of work, one accountable team.
Each scope states what we do ourselves and what stays with licensed contractors, so you know who is on your site before you award.

Scope 01
Structured cabling
The cabling plant is the part of a building that every other system depends on and nobody sees again once the floor tiles go down or the ceilings close. That is as true of a school or a hospital as of a data center. We install it to the drawings, test every link, and hand over records the operator can run the building from.
How it is delivered
Self-performed as a trade partner under the general contractor's schedule, safety plan and quality program.
Standards and methods: ANSI/TIA-568 · ANSI/TIA-942 · ANSI/TIA-606 · ANSI/TIA-607 · NFPA 70
Scope
- Copper and fiber backbone and horizontal cabling
- Cabling for wireless access points and networked devices
- Pathways: ladder rack, cable tray, basket and conduit fill
- Racks, cabinets, containment and cable management
- MDF, IDF and meet-me room build-out
- Outlets for classrooms, offices, nurse stations and patient rooms
- Telecommunications grounding and bonding
- Termination, labeling, testing and certification of every link

Scope 02
Equipment and material supply
Long lead times stop more data center schedules than labor does. We take the bill of materials, confirm what is available and when, and deliver it kitted by room and by rack so crews are not sorting pallets on the dock.
How it is delivered
Supplied against your specification or an approved equal, with substitutions put to you in writing before anything is ordered.
Standards and methods: Bill of materials review · Lead-time tracking · Serial and asset records
Scope
- Switching, routing, wireless and optics
- Servers, storage and rack-level power
- Racks, cabinets, containment and accessories
- Copper and fiber cable, connectivity and patching
- Software licensing and support renewals
- Staging, asset tagging, kitting and delivery to site

Scope 03
General contracting
Some projects are mostly technology with a building around it: an equipment room, a network operations space, a fit-out where the cabling and the gear are the critical path. On those we take the prime contract and carry schedule, cost, quality and safety ourselves.
How it is delivered
We manage the contract and self-perform the low-voltage scope. Architecture, engineering and the other trades are carried by licensed partners.
Contract roles: Prime contractor · Teaming partner · Subcontract
Scope
- Technology rooms, equipment rooms and network spaces
- Tenant improvements and fit-outs led by the technology scope
- Preconstruction: scope review, estimating and schedule
- Subcontractor selection, buyout and coordination
- Quality control, safety and site documentation
- Closeout, turnover and warranty follow-through

Scope 04
Power and energy infrastructure
AI workloads have turned the data center into a power project first. We supply the equipment between the utility and the rack, and the low-voltage monitoring and controls cabling that lets the operator see all of it.
How it is delivered
Equipment is supplied by us. Line-voltage electrical work is performed by licensed electrical contractors, with our scope coordinated to theirs.
Standards and methods: Supply to specification · Monitoring and controls cabling
Scope
- Uninterruptible power systems and battery cabinets
- Rack and row power distribution
- Standby generation and battery energy storage, supplied to specification
- Power and environmental monitoring cabling
- Controls and building-management network cabling
- Coordination with the electrical contractor of record

Scope 05
Information technology
A room is not in service when the last cable is tested. The network has to be racked, configured and brought up, the systems that run the building have to exchange data, and someone has to answer when something changes. We carry that work under the same scope as the cabling and the supply.
How it is delivered
Delivered against a written scope, with one named lead from staging to handover, and support after turnover during business hours unless contracted otherwise.
Standards and methods: Configuration records · WCAG 2.1 AA and Section 508 for software
Scope
- Rack, stack and configuration of switching, wireless, servers and storage
- Site network bring-up, addressing and handover documentation
- Integration between building, monitoring and business systems
- Custom applications, dashboards and workflow automation
- Hardware and licensing specification, endpoint configuration and license lifecycle
- Support after turnover, during business hours unless contracted otherwise
Scope boundaries
What we do not self-perform.
Electronic security, access control and fire alarm systems are licensed trades, and so is line-voltage electrical work. We do not self-perform them. On a project that includes security, access control or fire alarm, we coordinate our cabling with the owner's or general contractor's licensed contractor; line-voltage work is performed by licensed electrical contractors. In a hospital, nurse call and clinical systems are outside our scope as well. We would rather be a narrow fit than a broad one.